Carmanhaas Laser marking system can be applied to the marking of all non-transparent materials. General optical system: Expanding the beam through the beam expander to improve the divergence angle, after the beam combines the indicator light into the galvanometer system for beam deflection and scanning,finally, the workpiece is scanned and focused by the F-THETA scan lens.

Laser marking optical components mainly include beam expander and F-THETA scan lenses.The role of the beam expander is to enlarge the beam diameter and reduce the beam divergence angle. F-Theta scan lenses achieves uniform focusing of the laser beam.


  • Wavelength: 1064nm, 532nm, 355nm
  • Application: Laser Marking Machine
  • Marking Area: 50x50mm-600x600mm
  • Focal Length: 163mm,254mm,360mm,430mm
  • Brand Name: CARMAN HAAS
  • Product Detail

    Product Tags

    Product Description

    Carmanhaas Laser marking system can be applied to the marking of all non-transparent materials. General optical system: Expanding the beam through the beam expander to improve the divergence angle, after the beam combines the indicator light into the galvanometer system for beam deflection and scanning,finally, the workpiece is scanned and focused by the F-THETA scan lens.
    Laser marking optical components mainly include beam expander and F-THETA scan lenses.The role of the beam expander is to enlarge the beam diameter and reduce the beam divergence angle. F-Theta scan lenses achieves uniform focusing of the laser beam.

    Product Advantage:

    (1) High damage threshold coating (damage threshold: 40 J/cm2, 10 ns);
    Coating absorption <20 ppm. Ensure that the scan lens can be saturated at 8KW;
    (2) Optimized index design, collimation system wavefront < λ/10, ensuring diffraction limit;
    (3) Optimized for heat dissipation and cooling structure, ensuring no water cooling below 1KW, temperature <50°C when using 6KW;
    (4) With a non-thermal design, the focus drift is <0.5mm at 80 °C;
    (5) Complete range of specifications, customers can be customized.

    Technical Parameters:

    Fiber Laser F-Theta Scan Lenses (1064nm)

    Part Description

    FL(mm)

    Scan Field

    (mm)

    Max Entrance

    Pupil (mm)

    Working Distance  (mm)

    Mounting

    Thread

    SL-1064-50-63

    63

    50x50

    12

    78

    M85x1

    SL-1064-50-80

    80

    50x50

    12

    91

    M85x1

    SL-1064-70-100

    100

    70x70

    12

    108.3

    M85x1

    SL-1064-90-130

    130

    90x90

    12

    144

    M85x1

    SL-1064-110-160

    160

    110x110

    12

    170.2

    M85x1

    SL-1064-150-210

    210

    150x150

    12

    240.3

    M85x1

    SL-1064-175-254

    254

    175x175

    14

    295.4

    M85x1

    SL-1064-200-290

    290

    200x200

    14

    314.9

    M85x1

    SL-1064-220-330

    330

    220x220

    14

    343.7

    M85x1

    SL-1064-270-380

    380

    270x270

    14

    397.1

    M85x1

    SL-1064-300-420

    420

    300x300

    14

    437.1

    M85x1

    SL-(1030-1090)-175-254-(20CA)

    254

    175x175

    20

    278.2

    M85x1

    SL-1064-400-525-(20CA)

    525

    400x400

    20

    567

    M85x1

    SL-1064-450-650-(20CA)

    650

    450x450

    20

    720

    M85x1

    SL-1064-560-800-(20CA)

    800

    560x560

    20

    861

    M85x1

    SL-(1030-1090)-116-165-(12CA)

    165

    116x116

    12

    187.6

    M85x1

    SL-(1030-1090)-112-160

    160

    112x112

    10

    188.6

    M85x1

    UV Laser F-Theta Scan Lenses (355nm)

    Part Description

    FL(mm)

    Scan Field

    (mm)

    Max Entrance

    Pupil (mm)

    Working Distance  (mm)

    Mounting

    Thread

    SL-355-70-100

    100

    70x70

    10

    134

    M85x1

    SL-355-110-170

    170

    110x110

    10

    217.6

    M85x1

    SL-355-150-210

    210

    150x150

    10

    249

    M85x1

    SL-355-175-254

    254

    175x175

    10

    306.7

    M85x1

    SL-355-220-330

    330

    220x220

    10

    384.2

    M85x1

    SL-355-300-420

    420

    300x300

    10

    482.3

    M85x1

    SL-355-520-750

    750

    520x520

    10

    824.4

    M85x1

    SL-355-610-840-(15CA)

    840

    610x610

    15

    910

    M85x1

    SL-355-800-1090-(18CA)

    1090

    800x800

    18

    1193

    M85x1

    Green Laser F-Theta Scan Lenses (532nm)

    Part Description

    FL(mm)

    Scan Field

    (mm)

    Max Entrance

    Pupil (mm)

    Working Distance  (mm)

    Mounting

    Thread

    SL-532-40-65

    65

    40x40

    10

    73.5

    M85x1

    SL-532-70-100

    100

    70x70

    12

    114

    M85x1

    SL-532-110-160

    160

    110x110

    12

    180

    M85x1

    SL-532-150-210

    210

    150x150

    12

    232.5

    M85x1

    SL-532-175-254

    254

    175x175

    12

    287

    M85x1

    SL-532-220-330

    330

    220x220

    12

    355

    M85x1

    SL-532-350-500

    500

    350x350

    12

    539

    M85x1

    SL-532-165-255-(20CA)

    255

    165x165

    20

    294

    M85x1

    SL-532-235-330-(16CA)

    330

    235x235

    16

    354.6

    M85x1

    Packaging

    8. Lens packing

  • Previous:
  • Next:

  • related products